The temperature and pressure relief valve, usually called the T&P valve, sits on the top or side of your water heater with a pipe running down from it. It is the last line of defense if the thermostat fails or the pressure climbs. When it leaks, the cause is one of a handful of things. This page walks through them in the order we check. If the heater is old and the valve is only one of several problems, see water heater replacement.

What a T&P valve does

Illinois Plumbing Code section 890.1230 says all water heating and hot water storage equipment needs a pressure relief valve and a temperature relief valve, or one combination pressure-temperature valve, installed at the time of installation. The temperature sensor sits in the hottest water in the top 6 inches of the tank. It opens fully when the stored water reaches 210°F. The pressure side is set no higher than the heater's working pressure and never above 150 psi (890.1230). If either limit is hit, the valve opens and sends water out through the discharge pipe, so the tank does not build up danger.

Illinois rules for the discharge pipe

The same section sets rules for what happens after the valve opens. These are the ones we get called about most.

RuleWhat the code says
Temperature settingOpens full at 210°F
Pressure settingNo higher than the heater's working pressure, never above 150 psi
Discharge endWithin 6 inches of the floor or receptor, end not threaded
PipeMetallic, drains continuously downward, no reduced coupling or valve
Shut-offNo check valve or shut-off valve between the safety device and the heater, and none in the discharge pipe
Where it drainsIndirectly into a floor drain, hub drain, service sink, sump or trapped and vented P-trap in the same room as the heater
Not allowedDischarging through a wall to the outside or anywhere it could freeze

Source: 77 Ill. Adm. Code 890.1230. The reasons are practical. A valve with a shut-off behind it cannot relieve pressure when it has to. So does a discharge pipe that ends in a plug. A pipe that runs outside can freeze shut. If yours has a cap on the end, a threaded fitting or a hose clamp, it is not to code, and it is not safe.

Why a relief valve drips

The pressure is too high

If your water pressure from the street is high, the heater may see it too. The T&P valve is set to relieve pressure above its limit. A pressure test with a gauge on a hose bib tells us fast. If the house pressure is the issue, a pressure reducing valve helps. National guides put a replacement at $200 to $700 (HomeGuide).

Thermal expansion

Water expands when it heats. In a house where the incoming line has a check valve or a pressure reducing valve, the extra volume has nowhere to go back to the street, so pressure rises each time the heater cycles. The relief valve then drips a little after each cycle. The usual cure is an expansion tank, which gives the water a place to go. National guides put one at $150 to $450 installed (Angi, HomeGuide).

Here is what the code says on expansion tanks, stated exactly. Section 890.1220 requires an expansion tank on water heaters that are also used for space heating, where a single check valve in the cold line must be paired with a properly sized and approved expansion tank with no shut-off valve between the heater and the tank (77 Ill. Adm. Code 890.1220). The section names only that case. A plumber can still recommend one when thermal expansion is the cause, and it is often the right fix.

The valve is worn out or stuck

Minerals can leave the seat of a valve with a tiny leak. Minerals in hard water (9 to 21 grains per gallon in Rockford) are one possible cause. You can lift the test lever on the valve for a second and let it snap shut, but older valves sometimes fail to seat after that. If a valve starts to drip after testing and does not stop, replace it. Valves are a low-cost part, and replacing one with the tank drained is routine for us.

The water is too hot

A failed thermostat or a bad gas control can run a heater well above its setting. Then the temperature side of the valve opens at 210°F. That is the valve working as intended. Hot water that scalds at the tap is a warning sign (showers also need an anti-scald valve, see shower valve repair). Turn the heater off and call us.

How we diagnose a leaking relief valve

We check in a set order. First we look at the discharge pipe, to see whether the leak is the valve or a fitting above it. Then we put a gauge on a hose bib and read the house pressure, and we watch the gauge while the heater cycles. If the pressure climbs each time the heater fires, thermal expansion is the cause. Next we check the stored water temperature against the thermostat setting. Last we look at the valve itself. If pressure and temperature are fine and the valve still drips, the valve is the problem, and we replace it with the tank drained.

A replacement valve has to suit the tank, with the sensor in the hottest water in the top 6 inches, and the discharge pipe has to meet the rules in the table above: metallic, running downward, ending within 6 inches of the floor or receptor.

When a leaking relief valve is an emergency

Treat it as an emergency when the valve is running water steadily and not just dripping, when the water coming out is very hot or steaming, when the tank is rumbling or making loud noises, or when the discharge pipe is capped or missing. Turn off the power or gas to the heater at the breaker or the gas control. Close the cold water supply to the tank. Keep people and pets clear of the discharge area. Call us right away. Do not plug the valve, do not close anything on the discharge line, and do not stand near a tank that is making noise.

A slow drip every few hours is not an emergency, but it is not a thing to ignore either. It means pressure or heat is reaching the limit, or the valve is worn. Either way it needs a fix. If the tank itself is old, ask about the swap at the same visit. Our guide on water heater age covers the signs. Prices are on our plumber cost page.

Want a price for your own house?

Call, text, or send the form. You get a price back before any work is scheduled.

Quick answers

Why is my water heater relief valve dripping?

The usual causes are high water pressure, thermal expansion in a closed system, a worn valve seat, or water that is running too hot. A pressure test and a thermostat check tell us which one it is.

What temperature does a T&P valve open at in Illinois?

Illinois Plumbing Code 890.1230 says the temperature relief valve opens full at 210°F. The pressure relief is set no higher than the heater's working pressure and never above 150 psi.

Can I cap or plug a leaking relief valve?

Never. Illinois code bars any shut-off valve between the safety device and the heater and any shut-off valve in the discharge pipe. A capped valve cannot release pressure, so the tank could be at risk.

Where should the relief valve discharge pipe end?

Within 6 inches of the floor or receptor, with the end not threaded. The code says it drains indirectly into a floor drain, hub drain, service sink, sump or trapped and vented P-trap in the same room. It may not discharge through a wall to the outside.

Does Illinois require an expansion tank on a water heater?

Section 890.1220 requires an expansion tank on heaters that are also used for space heating, where a single check valve sits in the cold line. The section names only that case, though a plumber may recommend one for thermal expansion on any heater.

How much does an expansion tank cost?

National cost guides put an installed expansion tank at about $150 to $450. See our plumber cost page.

Is a dripping relief valve an emergency?

A steady stream, very hot or steaming water, loud noises from the tank, or a missing or capped discharge pipe is an emergency. Turn off the power or gas, close the cold supply and call us. A slow drip should be fixed soon but is not urgent.

Can I replace a relief valve myself?

An owner-occupant of a single-family home may do their own plumbing in Rockford, and any helper they hire must be a licensed plumber. The tank has to be drained and the discharge pipe has to meet code. Read our guide on doing your own plumbing in Illinois first.